Configuration file for SoFi RT Written by Datalystica Ltd., Park innovAARE, 5234 Villigen, Switzerland March 2024 Version 1.3 compatible with SoFi RT higher than 9.5.1.4 --------------------------------------------------------------------------- PATHS path of executable: C:\ME2 engine path of input files: D:\User\Desktop\ACSM;D:\User\Desktop\Xact path for scan-wise results (CMB): D:\User\Desktop\CMB path of factor profiles from file: D:\User\Desktop\profiles_ACSM_Xact.itx path of BC data: D:\User\Desktop\AE33 path of other external data: tbd NAMES name of HDF result files (large files): AXA_RT name of txt result file (single scans): AXA_RT_txt name of prefix for input filename: ACSM_RTdata;Sample name of prefix for BC input filename: name of prefix for other external data: tbd DATA TYPE Data type: AMS UMR / Q-ACSM (without m/z 19 and 20) AMS specific: exclude CO2 related variables instrument type: ACSM;Xact;BC MODEL OPTIONS restart RT: 0.1 factor start: 10 factor end: 10 factor names: HOA, COA, BBOA, OOA, traffic, dust, regional, industry, sea_salt, sulfate nb. of iterations: 1 resampling: enabled, using defined classes rolling: enabled window length: 14 window shift: 1 between PMF: CMB after each scan stats tests (corr): disabled stats tests (comp.): disabled a value constraints: enabled name of constraints over pr: HOA,,0.3;COA,,0.3;BBOA,,0.3;traffic,,0.0;dust,,0.0;regional,,0.0;industry,,0.0;sea_salt,,0.0;sulfate,,0.0 name of constraints over ts: